Sign In | Join Free | My himfr.com
Home > FLUKE >

Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex F377 FC

WUHU WANYI INDUSTRY CO.,LTD
Contact Now
    Buy cheap Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex F377 FC from wholesalers
     
    Buy cheap Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex F377 FC from wholesalers
    • Buy cheap Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex F377 FC from wholesalers

    Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex F377 FC

    Ask Lasest Price
    Brand Name : Fluke
    Model Number : Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex F377 FC
    Certification : CCCI
    Payment Terms : Western Union, T/T
    Supply Ability : 10-100
    Delivery Time : 7-10days
    • Product Details
    • Company Profile

    Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex F377 FC

    Product overview: Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex

    Voltage and current measurements with FieldSense™ technology

    The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.

    Measure extremely high current with iFlex® probe

    Use the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.

    Complete 3-phase measurements in quick, easy steps

    • Complete 3-phase voltage and current tests in 3 easy steps
    • Full set of phase-to-ground and phase-to-phase values calculated and shown on the meter
    • Values are also displayed on your smart phone and saved to the cloud via Fluke Connect software
    • Phase rotation auto-calculated and shown on the Fluke Connect software
    • No more hand-written notes or complicated math.

    Easy to see, easy to use with included tools

    Your job will get easier when you use the 377 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.

    Record, analyze, share results with Fluke Connect® software

    With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program.

    Specifications: Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex

    General specifications
    General Maximum Voltage between any Terminal and Earth Ground1000 V
    BatteryType2 AA IEC LR6 alkaline
    Life200 hour
    DisplayDual readout
    Automatic Power Off20 minutes
    Electrical
    AC Current: Jaw
    Range999.9 A
    Resolution0.1 A
    Accuracy2 % ±5 digits (45 Hz to 66 Hz)
    Crest Factor (50/60 Hz)3 @ 500 A
    2.5 @ 600 A
    1.42 @ 1000 A
    Add 2 % for C.F. >2
    AC Current: Flexible Current Probe
    Range2500 A
    Resolution1 A (≤2500 A) 0.1 A (≤999.9 A)
    Accuracy3 % ±5 digits (5 Hz to 500 Hz)
    Crest Factor (50/60Hz)3.0 at 1100 A
    2.5 at 1400 A
    1.42 at 2500 A
    Add 2 % for C.F. >2
    Position Sensitivity
    Flexible current probeDistance from Optimumi2500-10 Flexi2500-18 FlexError
    A0.5 in (12.7 mm)1.4 in (35.6 mm)± 0.5 %
    B0.8 in (20.3 mm)2.0 in (50.8 mm)± 1.0 %
    C1.4 in (35.6 mm)2.5 in (63.5 mm)± 2.0 %
    Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
    DC Current
    Range999.9 A
    Resolution0.1 A
    Accuracy2 % ±5 digits1
    [1]When using the ZERO function to compensate for offsets
    AC Voltage: Field Sense
    Range1000 V
    Resolution1 V (≤1000V)
    Accuracy≤4/0 AWG3 % ±5 digits (45 Hz to 66 Hz)
    ≥4/0 AWG5 % ±5 digits (45 Hz to 66 Hz)
    Position wire as close as possible to jaw opening (see illustration).Fluke 377 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex F377 FC
    AC Voltage: Test Leads
    Range600.0 V 1000 V
    Resolution0.1 V (≤600.0 V)
    1 V (≤1000 V)
    Accuracy1 % ±5 digits (20 Hz to 500 Hz)
    DC Voltage
    Range600.0 V
    1000 V
    Resolution0.1 V (≤600.0 V)
    1 V (≤1000 V)
    Accuracy1 % ±5 digits
    mV dc
    Range500.0 mV
    Resolution0.1 mV
    Accuracy1 % ±5 digits
    Amps Frequency: Jaw
    Range45 Hz to 66 Hz
    Resolution0.1 Hz
    Accuracy0.5 % ±5 digits
    Trigger Level5 Hz to 10 Hz, ≥10 A
    10 Hz to 100 Hz, ≥ 5 A
    100 Hz to 500 Hz, ≥ 10 A
    Amps Frequency: Flexible Current Probe
    Range5.0 Hz to 500.0 Hz
    Resolution0.1 Hz
    Accuracy0.5 % ±5 digits
    Trigger Level5 Hz to 20 Hz, ≥25 A
    20 Hz to 100 Hz, ≥20 A
    100 Hz to 500 Hz,≥25 A
    Resistance
    Range60.00 kΩ
    6000 Ω
    600.0 Ω
    Resolution0.1 Ω (≤600.0 Ω)
    1 Ω (≤6000 Ω)
    10 Ω (≤60.00 kΩ)
    Accuracy1 % ±5 digits
    Capacitance
    Range1000 μF
    Resolution0.1 μF (≤100.0 μF)
    1 μF (≤1000 μF)
    Accuracy1 % ±4 digits
    Mechanical
    Size (L x W x H)274 mm x 86 mm x 47 mm
    Weight (with Batteries)463 g
    Jaw Opening34 mm
    Flexible Current Probe Diameter7.5 mm
    Flexible Current Probe Cable Length (head to electronics connector)1.8 m
    Rogowski Coil Length450 mm
    Environmental
    Operating Temperature-10 °C to 50 °C
    Storage Temperature-40 °C to 60 °C
    Operating Humidity (without condensation)Non condensing (<10 °C)
    ≤90 % RH (10 °C to 30 °C)
    ≤75 % RH (30 °C to 40 °C)
    ≤45 % RH (40 °C to 50 °C)
    Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C >28 °C or <18 °C
    Ingress ProtectionIEC 60529: IP30 (jaw closed)
    Operating Altitude2000 m
    Storage Altitude12 000 m
    Electromagnetic Compatibility (EMC)
    InternationalIEC 61326-1: Portable Electromagnetic Environment
    IEC 61326-2-2, CISPR 11: Group 1, Class B
    Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
    Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.
    Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
    Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
    Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
    USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Safety
    GeneralIEC 61010-1: Pollution degree 2
    MeasurementIEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
    IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
    Current Clamp for Leakage Current MeasurementsIEC 61557-13: Class 2, ≤30 A/m
    Wireless Radio
    Radio Frequency CertificationFCC ID: T68-FBLE IC:6627A-FBLE
    Frequency Range2405 MHz to 2480 MHz
    Output Power<100 mW